Level Properties General tab

Contains controls that are used to set general options and symbology for a level.

Level Properties dialog box, General tab

  

Name

Lists the name of the selected level.

Description

Lists a description of the selected level.

File Name

Lists the name of file that the selected level is from. This file can be a reference or a level library.

Library

Lists the name of a library file, if one is used.

Number

Lists the level number.

Level numbers are not supported in DWG workmode.

Display

If on, turns on global display of the level. If off, the elements on the level are not displayed. However, if a cell placed on the level has elements in other levels, those elements are displayed.

Freeze

If on, freezes the selected level. When a level is frozen, elements on the level are not displayed. If a cell placed on the level has elements on other levels, none of the elements are displayed.

Lock

If on, elements on this level cannot be selected or edited.

Plot

If on, elements on this level can be printed. If off, the elements cannot be printed.

Symbology: ByLevel

Lists default settings for level symbology (Color, line Style, line Weight). When an element that uses ByLevel symbology is placed on the level, the element uses the symbology settings assigned to the level.

Symbology: Overrides

Lists override symbology (Color, line Style, line Weight) settings, which are view-dependent alternate settings for level symbology. When an element is placed on the selected level, it uses the symbology settings assigned to the level. To enable the view override settings, open the View Attributes dialog box (Settings > View Attributes) and turn on Level Symbology.

Symbology overrides are disabled in DWG workmode. All elements are displayed with ByLevel symbology.